About the sampling circuit.

Hardware design
June 30, 2020 by Jenelle 98

The temperature sampling circuit is not well understood, what is the role of the upper part of the circuit (the transistor), Pti+, PT1- is the sensor interface, VPT1+, VPT1- is connected to the CD4052 input.

a2706cf7b457c9c251d6c67174575b3.png

All Comments

user image

Abner Posted on June 30, 2020

The transistor should be a constant current circuit, and the sensor measurement should be based on the bridge principle.

0
user image

Kenan Posted on June 30, 2020

The input port part can be used as a temperature measurement sensor interface by the bridge mode, which is more beneficial to the measurement result.